A gutter cleared in November costs a morning or a small call-out. The same gutter left to overflow all winter can push water into a wall, and the damp that follows is a repair, a redecoration and an unhappy tenant. Planned maintenance is the cheapest work you will ever pay for, because it is the work that stops the expensive kind.
Three items in the year are the law in England: the gas safety check, the electrical inspection and the smoke and carbon monoxide alarms. The rest is good practice, and it is what keeps a home lettable for years with the same tenant in it. This checklist goes season by season, with the legal items marked as such.
It is about the building, not the paperwork. The landlord admin calendar covers the dates for certificates, tax and the tenancy. The regulations below were read on legislation.gov.uk, and HSE's legionella guidance on hse.gov.uk, on 16 November 2026.
The three legal items, with their intervals
| Item | The rule | Source |
|---|---|---|
| Gas safety check | Each gas appliance and flue you provide checked at intervals of not more than 12 months; the record to existing tenants within 28 days of the check, and to a new tenant before they move in | Gas Safety (Installation and Use) Regulations 1998, reg 36(3) and (6) |
| Electrical inspection | Every installation inspected and tested before a tenancy begins and at intervals of no more than 5 years, or sooner if the last report says so | Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, reg 3 |
| Smoke and carbon monoxide alarms | A smoke alarm on each storey with living accommodation; a carbon monoxide alarm in any room with a fixed combustion appliance other than a gas cooker; checked working on the day a new tenancy begins; repaired or replaced as soon as reasonably practicable after a tenant reports a fault | Smoke and Carbon Monoxide Alarm (England) Regulations 2015, reg 4 |
The gas check is the one that sets your year. Many landlords book it with the annual boiler service in early autumn, so the heating is checked before the first cold week. The gas safety check deadline guide explains how an early check keeps the date.
Legionella is a duty too, but not a calendar one. HSE says landlords must assess the risk from legionella in the water system, and that this "does not require an in-depth, detailed assessment". Most homes with mains water and no stored tanks are low risk. Do the assessment, keep a note of it, and review it from time to time and whenever something changes, such as a new boiler, a water tank or a long void.
Autumn: before the heating goes on
- Boiler service and gas safety check. One visit, one record, before the cold. The legal item of the season
- Bleed the radiators and check the pressure. Or show the tenant how, in writing
- Clear the gutters and downpipes. After the leaves fall, not before. Check the gullies at ground level drain
- Lag the outside taps and pipes in the loft. A burst pipe in January is the costliest leak of the year
- Check the loft. Insulation in place, no daylight through the roof, no signs of damp or nesting
- Test the alarms. Press the test button on each smoke and carbon monoxide alarm, at an inspection or a visit
Give the tenant a short note on keeping the home warm and aired through winter. Condensation is cheaper to prevent than mould is to treat.
Winter: watch for water and damp
- Look for condensation and mould. On window reveals, behind wardrobes on outside walls, in bathrooms. Check the extractor fans run and the trickle vents open
- Check the roof after storms. From the ground, with binoculars if needed: slipped slates, flashing lifted, gutters hanging
- Keep a plumber's number to hand. And tell the tenant where the stopcock is before they need it
- Empty property? Keep the heating on low and visit weekly, or drain the system. A void through a freeze is when pipes burst unnoticed
Winter is when damp reports come in. Treat each one as a repair, not a lifestyle complaint: find the cause, write down what you did, and go back to check it worked.
Spring: the outside of the building
- Walk round the outside. Pointing, render, cracks, window frames, sills, doors. Note anything that has moved since last year
- Clear the drains. Lift the inspection covers and check the flow; a blocked drain found in April is a rod, not a dig
- Check fences, gates and paths. Loose paving and broken fences are trip and security risks; the tenancy agreement says who looks after them
- Service the extractor fans. Clean the grilles; replace the ones that have slowed
- Book the summer jobs. Painters and roofers get busy; book for dry months now
Spring is also a good time for the six-monthly inspection, so you see the home after the wettest months. How often to inspect covers the notice and the record.
Summer: the work that needs dry weather
- Exterior decoration. Windows, doors, fascias and soffits. Paint protects timber; peeling paint lets water in. A repaint every few years is far cheaper than replacing rotten frames
- Roof and chimney work. Repointing a stack, replacing flashing, clearing moss
- Trees and hedges. Cut back anything near the roof, gutters or drains, outside the nesting season
- Void works. If a tenancy ends, summer is the easiest time for the jobs that need an empty home
The electrical inspection is the other legal item to watch. It falls due at most every 5 years, or sooner if the last report says so, and a valid report must be in place before each new tenancy. Book it a few months ahead; an inspection that finds work needed can take weeks to put right.
At every change of tenant
The start of a tenancy has its own short list, because the law looks at that day:
- 1Alarms checked working on the day the tenancy begins. Write down that you did it (reg 4(1)(b))
- 2The latest gas safety record to the tenant before they move in (reg 36(6)(b))
- 3A valid electrical report. Inspected before the tenancy begins, within the last 5 years unless the report set an earlier date (reg 3)
- 4The legionella assessment reviewed if the home stood empty for a while
- 5The check-in inventory, with photographs, as the record of what you handed over
The repairs workflow guide covers the reactive side: the repairs tenants report between these planned visits.
The year, set up once
Every planned job on one board, with its reminder. In LetCompliance the maintenance board shows planned servicing and safety checks, such as the alarm tests, across every property, with a reminder before each is due. Certificate reminders go out at 90, 30, 14, 7 and 1 days before the gas record or the electrical report runs out. The calendar feed puts every date, from the boiler service to the next inspection, into Google, Apple or Outlook calendar with an alarm. All of this is on every plan. Single, for one property, is £7.99 a month.