Skip to main content
LetCompliance

Landlord glossarySafety

C1, C2, C3 and FI Codes (Electrical Report)

The codes an electrician gives each problem in an electrical installation condition report, from C1 (danger present) to FI (further investigation required). C2 means potentially dangerous and C3 improvement recommended. In a private let in England, a report that needs remedial work or further investigation means the work must be done within 28 days, or sooner if the report says so, and the landlord sends the electrician’s confirmation to the tenant and the council within 28 days of the work.

Collect the rent, log every cost and keep the tax figures ready, from £7.99 a month.

Checked against GOV.UK and legislation.gov.ukLast reviewed 16 November 2026How facts are checked

C1 and C2
Remedial work needed
FI
Further investigation needed
C3
Recommended, not required
Deadline
28 days, or sooner if the report says

Why it matters

What C1, C2, C3 and FI Codes (Electrical Report) means for a landlord

A report with any C1, C2 or FI is unsatisfactory, and the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 then require the work within 28 days of the inspection, or the shorter period the report gives, followed by confirmation from a qualified person that the standards are met. A council can impose a penalty of up to £40,000 for a breach of the electrical safety duties. Wales requires electrical testing at least every five years under its fitness for human habitation rules, and in Scotland it is part of the Repairing Standard. Related: EICR (Electrical Installation Condition Report), Fitness for Human Habitation and Civil Penalty Notice.

Common mistakes

Where landlords go wrong

  1. 01Treating a C3 as work that must be done before the report is satisfactory.
  2. 02Getting the work done but not sending the confirmation to the tenant and the council.
  3. 03Counting the 28 days from the day the report arrived, not the day of the inspection.

What to do

A short checklist

  • Book remedial work as soon as a report shows C1, C2 or FI.
  • Send the confirmation and the report to the tenant and the council within 28 days of the work.
  • Track the next test date with the certificate renewal calculator.

LetCompliance reads the gas safety, EICR and EPC dates from each upload: landlord certificates in one place, with an email before each one expires. See plans and prices

Sources

Checked against these sources on 16 November 2026. A guide to the rules in England, not legal advice: for a dispute or a possession claim, speak to a solicitor.